Hi,
This one seems to be on all versions of ProIV, that have LS Entry Logic available.
If you have a screen function and do a GLOBAL_LSCALL in After Field of a field that can get input, and the Global function that is called is a Screen and has Default Logic, but has NO Entry logic, then if the user pressed TAB on the first screen then Default Logic in the GLOBAL_LSCALL'ed function does not get executed. But the LS does run without the Default Logic being executed.
To fix this, just put in some dummy logic in Logic Entry to LS1 in the Global Function...
Bit scary eh!
Rob.
Default Logic not getting executed
Started by Rob Donovan, Aug 18 2006 02:58 PM
2 replies to this topic